PS Series Proximity Sensors
Part Number = PS[A][B][C][D]
EX: PS20-8DNUF = PS20mm Square Body, 8mm Sensing Distance (A), NPN Normally Open DC (B), Top Sensing (C), Frequency Offset (D)
Download PS Series Spec Sheet ยป
[A] Size & Distance |
||||||
[A] | Size | Sensing | Associated | |||
[B] | [C] | [D] | ||||
12-4 | 12mm | 4mm (Front/Top) |
DN, DP, DN2 | [BLANK], U | [BLANK] | |
17-3 | 17mm | 3mm (Front/Top) |
DN, DP, DN2 | [BLANK] | [BLANK] | |
17-5 | 17mm | 5mm (Front/Top) |
DN, DP, DN2 | [BLANK], U | [BLANK] | |
T17-5 | 17mm | 5mm (Front) |
DO, DC | [BLANK], U | [BLANK] | |
17-8 | 17mm | 8mm (Front/Top) |
DN, DP | [BLANK], U | [BLANK] | |
20-8 | 20mm | 8mm (Front/Top) |
DN, DP, DN2 | [BLANK], U | [BLANK], F | |
25-5 | 25mm | 5mm (Front) |
DN, DP, DN2, AO, AC | [BLANK] | [BLANK] | |
30-10 | 30mm | 10mm (Front) |
DN, DP, DN2, AO, AC | [BLANK] | [BLANK] | |
30-15 | 30mm | 15mm (Front) |
DN, DP, DN2, AO, AC | [BLANK] | [BLANK] | |
35-10 | 35mm | 10mm (Front/Side) |
DN, DP, DN2, DP2, AO, AC | [BLANK], S | [BLANK] | |
35-15 | 35mm | 15mm (Front/Side) |
DN, DP, DN2, DP2, AO, AC | [BLANK], S | [BLANK] | |
40-20 | 40mm | 20mm (Front) |
DN, DN2, DP, AO, AC | [BLANK] | [BLANK] | |
50-30 | 50mm | 30mm (Bottom) |
DN, DP, DN2, DP2 | [BLANK] | [BLANK] |
[B] Supply & Output |
||||
[B] | Current | Output | Voltage | Wire |
DN | DC | NPN – Normally Open | 10-30 | 3-wire |
DN2 | DC | NPN – Normally Closed | 10-30 | 3-wire |
DP | DC | PNP – Normally Open | 10-30 | 3-wire |
DP2 | DC | PNP – Normally Closed | 10-30 | 3-wire |
AO | AC | Normally Open | 90-250 | 2-wire |
AC | AC | Normally Closed | 90-250 | 2-wire |
[C] Sensing Orientation |
|
[Blank] | Standard Front Sensing |
S | Side Sensing |
U | Top Sensing |
[D] Frequency Offset |
|
[Blank] | Standard Frequency |
F | Sensor Frequency is offset from standard in order to reduce “crosstalk” when multiple sensors are mounted next to each other. (Available only on 20mm SQ-Face Version, 20-8.) |