SELECTION
GUIDE
Part Number = PS [ A ] [ B ] [ C ] [ D ]
(Example: PS12 - 4DN = 12mm
Square Body, 4mm Sensing Distance, DC - NPN) |
Option
[ A ] |
Body Size
(Length x Width of Face)
- Nominal Sensing Distance
|
12 -
4
 |
12mm SQ
Face - Sensing distance
= 4mm (front or top sensing)
OPTION [B] = DN, DP, DN2
OPTION [C] = [BLANK], U
OPTION [D] = [BLANK]
Download
Specifications
|
17 -
3
 |
17mm SQ Face -
Sensing
distance = 3mm (front or top sensing)
OPTION [B] = DN, DP, DN2
OPTION [C] = [BLANK]
OPTION [D] = [BLANK]
Download
Specifications
|
17 -
5
 |
17mm SQ Face -
Sensing
distance = 5mm (front or top sensing)
OPTION [B] = DN, DP, DN2
OPTION [C] = [BLANK], U
OPTION [D] = [BLANK]
Download
Specifications
|
T17 -
5
 |
17mm SQ Face - Sensing
distance = 5mm (front sensing only), 2-Wire
OPTION [B] = DO, DC
OPTION [C] = [BLANK], U
OPTION [D] = [BLANK]
Download
Specifications
|
17 -
8
 |
17mm SQ Face -
Sensing
distance = 8mm (front or top sensing)
OPTION [B] = DN, DP
OPTION [C] = [BLANK], U
OPTION [D] = [BLANK]
Download
Specifications
|
20 -
8
 |
20mm SQ Face -
Sensing
distance = 8mm (front or top sensing)
OPTION [B] = DN, DP, DN2
OPTION [C] = [BLANK], U
OPTION [D] = [BLANK], F
Download
Specifications
|
25 -
5
 |
25mm SQ Face -
Sensing
distance = 5mm (front sensing only)
OPTION [B] = DN, DP, DN2, AO, AC
OPTION [C] = [BLANK]
OPTION [D] = [BLANK]
Download
Specifications
|
30 -
10
 |
30mm SQ Face -
Sensing
distance = 10mm (front sensing only)
OPTION [B] = DN. DP, DN2, AO, AC
OPTION [C] = [BLANK]
OPTION [D] = [BLANK]
Download
Specifications
|
30 -
15
 |
30mm SQ Face -
Sensing
distance = 15mm (front sensing only)
OPTION [B] = DN. DP, DN2, AO, AC
OPTION [C] = [BLANK]
OPTION [D] = [BLANK]
Download
Specifications
|
35 -
10
 |
35mm SQ Face -
Sensing
distance = 10mm (front or side sensing)
OPTION [B] = DN, DP, DN2, DP2, AO, AC
OPTION [C] = [BLANK], S
OPTION [D] = [BLANK]
Download
Specifications
|
35 -
15
 |
35mm SQ Face -
Sensing
distance = 15mm (front or top sensing)
OPTION [B] = DN, DP, DN2, DP2, AO, AC
OPTION [C] = [BLANK], S
OPTION [D] = [BLANK]
Download
Specifications
|
40 -
20
 |
40mm SQ Face -
Sensing
distance = 20mm (front sensing only)
OPTION [B] = DN, DN2, DP, AO, AC
OPTION [C] = [BLANK]
OPTION [D] = [BLANK]
Download
Specifications
|
50 -
30
 |
50mm SQ Face -
Sensing
distance = 30mm (bottom sensing only)
OPTION [B] = DN, DP, DN2, DP2
OPTION [C] = [BLANK]
OPTION [D] = [BLANK]
Download
Specifications
|
Option
[ B ] |
Supply
& Output Type
|
| DN |
NPN
- Normally Open
10 - 30 VDC |
| DN2 |
NPN
- Normally Closed
10 - 30 VDC |
| DP |
PNP
- Normally Open
10 - 30 VDC |
| DP2 |
PNP
- Normally Closed
10 - 30 VDC |
| AO |
Normally
Open AC, 2-wire
90 - 250 VAC |
| AC |
Normall
Closed AC 2-wire
90 - 250 VAC |
Option
[ C ] |
Sensing
Orientation
|
| [BLANK] |
Standard
Front Sensing |
| S |
Side
Sensing |
| U |
Top
Sensing |
Option
[ D ] |
Frequency
Offset
|
| [BLANK] |
Standard
Frequency |
| F |
Sensor
Frequency is offset from standard in order to reduce "crosstalk"
when multiple sensors are mounted next to each other
(available only on 20mm SQ Face Versions (OPTION [A] = 20 - 8) |
| |
|